Foundation Specialists - British Columbia
604-270-4773
info@terracana.ca
1556Sheet Piles·21Pipe Piles·980mWall Length·3,650 m²Total Area·ZeroRail Disruptions·1556Sheet Piles·21Pipe Piles·980mWall Length·3,650 m²Total Area·ZeroRail Disruptions·

Pipe and Sheet Pile Foundation
for Dyke at Queens Reach

980m Dyke Wall Installed Next to Active Rail Lines Using Excavator-Mounted Vibratory Pile Driver
Queens Reach, Surrey, BC
April 2018

In the spring of 2018, TerraCana was asked by a repeat client to bid with them on a public tender for the installation of a Sheet Pile Foundation for a dyke wall. This wall, located in Surrey, was to be approximately 980m long for a total of 3,650 sq.m of 14-770 piles.

The Challenge

The tight confines of the allowed working area, along with the proximity to rail lines, limited the installation of piles due to both physical constraints and time constraints. Moreover, workers quickly discovered that the starting area had been backfilled with old car parts and boulders. Additionally, logistical difficulties arose from the various sizes in the sheet pile design. Furthermore, changes in pile sizes during the project added to the challenges.

The Solution

In preparation for the variety of pile sizes, TerraCana extensively planned the order for cutting and shipping piles to the site, resulting in minimal wastage on the project. This thorough preplanning also facilitated easier resolution of issues related to the engineer’s adjustments to pile lengths. The GC also had to remove significant obstructions that property owners had backfilled over the decades. Lastly, TerraCana’s use of an excavator-mounted vibratory pile driver required minimal space for pile installation and reduced the number of shadows required by the rail company compared to using a crane.

The Outcome

TerraCana completed the 980m dyke wall with minimal wastage through thorough preplanning, navigating active rail lines, buried obstructions and mid-project design changes.

Technical Specifications

No. of Sheet Piles
1556
No. of Pipe Piles
21
Pile Type
12-3/4 inch Pipe with Double Helix
Wall Length
980 metres
Application
Commercial

Key Outcomes

980m dyke wall completed with minimal wastage through thorough preplanning
Active rail line constraints navigated with excavator-mounted vibratory pile driver
Buried obstructions and mid-project design changes successfully managed

Equipment

Pile Installation
Excavator-mounted vibratory pile driver

Queens Reach, BC

Working on a similar project?

Get a quote from TerraCana’s engineering team.