Foundation Specialists - British Columbia
604-270-4773
info@terracana.ca
12Pipe Piles Installed·4.5"Pile Diameter·1Sacrificial Load Test·ZeroNoise Complaints·IndoorInstallation·12Pipe Piles Installed·4.5"Pile Diameter·1Sacrificial Load Test·ZeroNoise Complaints·IndoorInstallation·
Industrial – Small Diameter Pipe Piles

Indoor Deep Foundation Installation

Small Diameter Pipe Pile Foundation for Great Little Box Co. in Richmond BC
Richmond, BC
March 2015

The Great Little Box printing company wanted to install a new industrial-size printer in its Richmond facility. The new printer required a foundation that could handle a heavy load. Because of this, our design team recommended a deep foundation for stability and strength.

The Challenge

Since the project site was indoors, the building posed a number of limitations. Most importantly, it was sensitive to noise and vibration. In addition to this, the amount of spoils produced needed to be kept to a minimum. With these factors in mind, the final foundation needed to be able to withstand the full weight of the new printer.

The Solution

TerraCana’s design team used small diameter pipe piles to meet the strict performance requirements. Pipe piles can be installed with minimal site disturbance and can support heavy loads. To verify the pile performance, we preloaded each pile after installation and performed a sacrificial load test.

The Outcome

The foundation was successfully installed indoors with minimal noise, vibration and spoils, meeting all performance requirements to support the full weight of the new industrial printer.

Technical Specifications

No. of Piles
12 plus 1 test
Pile Type
Small diameter pipe pile: 4.5 inch diameter
Application
Industrial

Key Outcomes

Foundation installed indoors with minimal noise and vibration
Spoils kept to a minimum throughout installation
All piles preloaded and performance verified with sacrificial load test

Richmond, BC

Working on a similar project?

Get a quote from TerraCana’s engineering team.